Common defects in common areas

1 Architectural elements a) Hairline cracks, discolouration and efflorescence to external walls b) Unregulated use of glass in handrails c) Chipped and/or cracked wall and floor tiles Read also Ignorance is not bliss for strata property owners Different ways to check new and secondary market properties d) Inter-floor water leaks due to waterproofing issues with swimming pools, concrete flat roofs or elevated gardens e) Lack of proper gradient (falls), causing stagnant water and clogged floor traps f) Poorly-fitted timber doors and aluminum windows g) Inoperable fire doors (not closing properly) h) Rainwater splashing into lift lobbies i) Premature rust and corrosion for exposed metal elements 2 Civil & Structural Engineering elements a) Recurrent water seepage after PU injection grouting b) Water seepage through water tanks, concrete slabs and swimming pools c) Water seepage through construction joints d) Concrete shrinkage cracks e) Stagnant water on roads and in drains with inadequate gradient (falls) 3 Mechanical, Electrical and Plumbing (MEP) Engineering elements a) MEP installation not thoroughly tested and commissioned b) Fire protection system with unresolved faulty signals c) Unregulated residual current devices (RCD) for electrical installations d) Burst water pipes due to cracking e) Water seepage in M&E rooms – lift motor rooms, electrical switch rooms 4 Inaccessible or hard-to-reach common areas overlooked during inspection a) Plant and equipment rooms – lift motor rooms, electrical switch boards, gen-set, pumps b) Functionality of fire-fighting systems c) Sewerage and rainwater pipes concealed  in boxed-up risers d) Water tanks, submersible equipment,  embedded cables and in-ceiling installations e) High-level wall facades, windows, skylights and roofs f) Escape staircases g) Basement walls h) Concealed services – especially areas covered with ceilings and ID finishes i) Desk studies – adequate, accurate, endorsed, approved and as-built drawings, documentations and warranties provided to the JMB or property manager for purposes of maintenance and management (Source: Anthony Lee Tee of Architect Centre Sdn Bhd) This story first appeared in the EdgeProp.

READ MORE

Rising awareness on healthier workplaces

Malaysian Institute of Architects president Datuk Ezumi Harzani Ismail deems that in terms of working space planning, Malaysia is doing fine for now as there are more new buildings with airy green common spaces.

READ MORE

PAM: Resolve disputes by using common sense approach

KUALA LUMPUR (Dec 19): Consultants are encouraged to apply common sense approach and play facilitative roles in helping contracting parties to resolve contractual disputes due to COVID-19, said Pertubuhan Akitek Malaysia (PAM) president Datuk Ar.

READ MORE

Government has important role in pushing new building technology

PETALING JAYA (Sept 16): Government’s role is crucial in supporting the rollout of new construction technologies in the country and regulation is also important for the industry players to adapt to new building methods, said Hong Kong-based Ho & Partners Architects (HPA) executive chairman Nicholas Lik Chi Ho.

READ MORE

Time to shift to new building methods, says PAM president

PETALING JAYA (Sept 16): The Covid-19 pandemic may have hit the construction sector but it also opened up a new avenue for the industry players to rethink the conventional construction process and start to embrace Industrialised Building System (IBS) and Modular Integrated Construction (MiC), said Malaysian Institute of Architects (PAM) president Datuk Ezumi Harzani Ismail.

READ MORE

Is your property healthy?

On a scale of 1 to 10 (with 1 being the best and 10 the poorest), Architect Centre accredited building inspector and trainer Anthony Lee Tee ranked most properties he has visited in Malaysia, a 7 to even 10.

READ MORE